A working notebook

Better questions.
More useful models.

A concise set of modeling habits, review questions and documentation links for structural performance studies.

Start with the mechanics

Make the assumptions visible

01 / Units

One consistent unit system

Record the base units for force, length and time. Derive stress, density, acceleration and energy from those choices; check imported material data and loading records against them.

02 / Materials

Use laws that answer the question

Select constitutive behavior for the mechanisms and loading path of interest. Record parameter sources and distinguish measured properties from calibrated values.

03 / Interfaces

Resolve how components interact

State whether interfaces are tied, bonded, frictional or allowed to separate. Review whether assumed compatibility suppresses slip, opening or another relevant mechanism.

04 / Boundaries

Represent the actual restraint

Review support flexibility, connection releases, symmetry and the way forces enter the model. Compare the assumed restraint with the physical test or intended structural condition.

Before accepting the result

Check the calculation. Compare the physics.

Verification

Ask whether the chosen mathematical model is being solved as intended.

  • Check connectivity, releases and unintended rigid-body motion.
  • Review reactions, load balance and a simple elastic benchmark.
  • Investigate mesh, increment and convergence sensitivity.
  • Inspect warnings and the response near failed increments.

Validation

Ask whether the model represents the physical response needed for the intended use.

  • Compare with relevant experimental observations.
  • Examine full response curves as well as peaks.
  • Compare deformation or damage patterns where evidence exists.
  • Report differences and the range supported by the comparison.

Keep calibration and validation distinct. Matching the data used to fit a model demonstrates the fit. Independent observations provide a stronger test of its predictive behavior.

What to save with the result

Retain the input version, solver settings, parameter definitions, load history, processing steps and selected output files. A reproducible record should explain how the reported curves and response measures were obtained.

Download the review checklist

When time is part of the problem

Three dynamic analysis checks

  1. Mass and modes. Review the source and distribution of mass. Inspect mode shapes for unintended mechanisms or unexpected restraint before interpreting response histories.
  2. Input and integration. Confirm excitation units, direction, scaling and sampling. Examine the sensitivity of key outputs to the integration time step.
  3. Damping and energy. State the damping model and its parameters. Inspect energy terms appropriate to the solver, especially when using a dynamic procedure to approximate quasi-static response.

Related documentation: CSI time-history analysis and the Abaqus quasi-static analysis guide.

Read the underlying documentation

Selected technical resources

Direct links to procedure documentation. Use the documentation that corresponds to your software version and analysis settings.

Common questions

A few useful distinctions

Is quasi-static analysis always cyclic?

No. Quasi-static means that inertia has a negligible influence on the response. Both monotonic loading and reversed cyclic loading can meet that condition.

Does convergence establish that a model is accurate?

Convergence indicates that the specified numerical criteria were met. Accuracy also depends on the physical idealization, input data, discretization and comparison with relevant evidence.

Does a finer mesh always give a better result?

Mesh refinement is useful when it improves the response quantities of interest. Review element quality, the material formulation and the mechanism being represented, then compare results over an appropriate range of mesh sizes.

What makes a numerical and experimental comparison useful?

Match loading and boundary conditions, define the compared quantities consistently, and examine both global response and observable mechanisms. State which data were used for calibration and which were used for an independent comparison.